Evaluation of a calibration transfer between a bench top and portable Mid-InfraRed spectrometer for cocaine classification and quantification.

J. Eliaerts N. Meert P. Dardenne F. V. Durme V. Baeten +2 lainnya

Abstrak

A portable Fourier Transform Mid-InfraRed (FT-MIR) spectrometer using Attenuated Total Reflectance (ATR) sampling is used for daily routine screening of seized powders. Earlier, ATR-FT-MIR combined with Support Vector Machines (SVM) algorithms resulted in a significant improvement of the screening method to a reliable and straightforward classification and quantification tool for both cocaine and levamisole. However, can this tool be transferred to new (hand-held) devices, without loss of the extensive data set? The objective of this study was to perform a calibration transfer between a newly purchased bench top (BT) spectrometer and a portable (P) spectrometer with existing calibration models. Both instruments are from the same brand and have identical characteristics and acquisition parameters (FT instrument, resolution of 4 cm-1 and wavenumber range 4000 to 500 cm-1). The original SVM classification model (n = 515) and SVM quantification model (n = 378) were considered for the transfer trial. Three calibration transfer strategies were assessed: 1) adjustment of slope and bias; 2) correction of spectra from the new instrument BT to P using Piecewise Direct Standardization (PDS) and 3) building a new mixed instrument model with spectra of both instruments. For each approach, additional cocaine powders were measured (n = 682) and the results were compared with GC-MS and GC-FID. The development of a mixed instrument model was the most successful in terms of performance. The future strategy of a mixed model allows applying the models, developed in the laboratory, to portable instruments that are used on-site, and vice versa. The approach offers opportunities to exchange data within a network of forensic laboratories using other FT-MIR spectrometers.

Topik & Kata Kunci

Penulis (7)

J

J. Eliaerts

N

N. Meert

P

P. Dardenne

F

F. V. Durme

V

V. Baeten

N

N. Samyn

K

K. Wael

Format Sitasi

Eliaerts, J., Meert, N., Dardenne, P., Durme, F.V., Baeten, V., Samyn, N. et al. (2020). Evaluation of a calibration transfer between a bench top and portable Mid-InfraRed spectrometer for cocaine classification and quantification.. https://doi.org/10.1016/j.talanta.2019.120481

Akses Cepat

Informasi Jurnal
Tahun Terbit
2020
Bahasa
en
Total Sitasi
21×
Sumber Database
Semantic Scholar
DOI
10.1016/j.talanta.2019.120481
Akses
Open Access ✓