Semantic Scholar Open Access 2017 21 sitasi

Comparing DXA and Air Displacement Plethysmography to Assess Body Composition of Male Collegiate Hockey Players

Patrick Delisle-Houde Ryan E. R. Reid Jessica A. Insogna Neal W. Prokop T. Buchan +2 lainnya

Abstrak

Abstract Delisle-Houde, P, Reid, RER, Insogna, JA, Prokop, NW, Buchan, TA, Fontaine, SL, and Andersen, RE. Comparing DXA and air-displacement-plethysmography to assess body composition of male collegiate hockey players. J Strength Cond Res 33(2): 474–478, 2019—Accurate assessment of body composition is an important consideration for athletes because it is a health/performance variable. However, little is known about the variability in values obtained across different assessment methods for specific athlete populations. The purpose of this study was to compare 2 common laboratory methods that assess body composition: air displacement plethysmography (BOD POD) and dual energy x-ray absorptiometry (DXA). Twenty-nine male collegiate hockey players, (Age = 24.07 ± 1.49, BMI = 26.5 ± 2.74) participated in this study. All participants underwent back-to-back BOD POD and DXA evaluations. Paired t-tests and Bland–Altman analyses were performed to compare differences in fat mass, fat percentage, and fat-free mass between methods. Average fat percentage reported by the DXA and BOD POD was 15.34 ± 3.53 and 11.66 ± 4.82 respectively, resulting in a bias score of 3.78 ± 2.33 kg (t(28) = 8.71, p ⩽ 0.001). Average fat mass reported by the DXA and BOD POD was 13.42 ± 3.59 and 10.15 ± 4.54 kg respectively, resulting in a bias score of 3.27 ± 1.92 kg (t(28) = 9.18, p ⩽ 0.001). Average fat-free mass reported by the DXA and BOD POD was 73.31 ± 5.30 and 76.25 ± 5.74 kg respectively, resulting in a bias score of −2.93 ± 2.06 kg (t(28) = −7.66, p ⩽ 0.001). Our findings can help make more insightful comparisons between studies that use different body composition methodologies among athletic populations.

Topik & Kata Kunci

Penulis (7)

P

Patrick Delisle-Houde

R

Ryan E. R. Reid

J

Jessica A. Insogna

N

Neal W. Prokop

T

T. Buchan

S

Shawn L. Fontaine

R

R. Andersen

Format Sitasi

Delisle-Houde, P., Reid, R.E.R., Insogna, J.A., Prokop, N.W., Buchan, T., Fontaine, S.L. et al. (2017). Comparing DXA and Air Displacement Plethysmography to Assess Body Composition of Male Collegiate Hockey Players. https://doi.org/10.1519/JSC.0000000000001863

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.1519/JSC.0000000000001863
Informasi Jurnal
Tahun Terbit
2017
Bahasa
en
Total Sitasi
21×
Sumber Database
Semantic Scholar
DOI
10.1519/JSC.0000000000001863
Akses
Open Access ✓