DOAJ Open Access 2023

High Isolation, Double-Clamped, Magnetoelectric Microelectromechanical Resonator Magnetometer

Thomas Mion Michael J. D’Agati Sydney Sofronici Konrad Bussmann Margo Staruch +4 lainnya

Abstrak

Magnetoelectric (ME)-based magnetometers have garnered much attention as they boast ultra-low-power systems with a small form factor and limit of detection in the tens of picotesla. The highly sensitive and low-power electric readout from the ME sensor makes them attractive for near DC and low-frequency AC magnetic fields as platforms for continuous magnetic signature monitoring. Among multiple configurations of the current ME magnetic sensors, most rely on exploiting the mechanically resonant characteristics of a released ME microelectromechanical system (MEMS) in a heterostructure device. Through optimizing the resonant device configuration, we design and fabricate a fixed–fixed resonant beam structure with high isolation compared to previous designs operating at ~800 nW of power comprised of piezoelectric aluminum nitride (AlN) and magnetostrictive (Co<sub>1-x</sub>Fe<sub>x</sub>)-based thin films that are less susceptible to vibration while providing similar characteristics to ME-MEMS cantilever devices. In this new design of double-clamped magnetoelectric MEMS resonators, we have also utilized thin films of a new iron–cobalt–hafnium alloy (Fe<sub>0.5</sub>Co<sub>0.5</sub>)<sub>0.92</sub>Hf<sub>0.08</sub> that provides a low-stress, high magnetostrictive material with an amorphous crystalline structure and ultra-low magnetocrystalline anisotropy. Together, the improvements of this sensor design yield a magnetic field sensitivity of 125 Hz/mT when released in a compressive state. The overall detection limit of these sensors using an electric field drive and readout are presented, and noise sources are discussed. Based on these results, design parameters for future ME MEMS field sensors are discussed.

Topik & Kata Kunci

Penulis (9)

T

Thomas Mion

M

Michael J. D’Agati

S

Sydney Sofronici

K

Konrad Bussmann

M

Margo Staruch

J

Jason L. Kost

K

Kevin Co

R

Roy H. Olsson

P

Peter Finkel

Format Sitasi

Mion, T., D’Agati, M.J., Sofronici, S., Bussmann, K., Staruch, M., Kost, J.L. et al. (2023). High Isolation, Double-Clamped, Magnetoelectric Microelectromechanical Resonator Magnetometer. https://doi.org/10.3390/s23208626

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.3390/s23208626
Informasi Jurnal
Tahun Terbit
2023
Sumber Database
DOAJ
DOI
10.3390/s23208626
Akses
Open Access ✓