Temperature Field Distribution Testing and Improvement of Near Space Environment Simulation Test System for Unmanned Aerial Vehicles
Abstrak
Temperature distribution inside the vacuum chamber of the TRX 2000(A) near space environment simulation test system (NSESTS) was investigated through both experimentation and computational fluid dynamics simulation. Comparison between the experimental result and the simulation result showed that these two results were very close to each other, validating the feasibility of using the simulation method to study the temperature distribution inside the NSESTS. Then, the effect of wind, either downwind or upwind, on temperature uniformity inside the NSESTS was investigated through the simulation method. The simulation result showed that the non-uniformity coefficient will be reduced from 0.2757 to 0.2012 (by 27.1%) in the case of downwind and to 0.2055 (by 25.5%) in the case of upwind. Then, the simulation result was validated by experiment. The result of this research indicates that the temperature uniformity can be greatly improved through installment of additional fans inside the NSESTS.