DOAJ Open Access 2025

New Hip Adductor Isometric Strength Test on Force Platform Shows Good and Acceptable Intra-Test Reliability for Peak Force Measurement

Pablo Merino-Muñoz Felipe Hermosilla-Palma Nicolás Gómez-Álvarez Jorge Pérez-Contreras Bianca Miarka +5 lainnya

Abstrak

<b>Background/Objectives</b>: Groin and hip injuries are common in sport, and muscle weakness has been identified as an intrinsic risk factor. So, analyzing the strength of the hip musculature becomes important. To date, there are no hip adductor isometric strength tests on force platforms. This study aims to analyze the intra-test reliability of a hip adductor strength test using force platforms. <b>Methods:</b> The study sample comprised 13 male professional soccer players with an average age of 22.3 ± 3 years, body mass of 75.8 ± 5.4 kg, and height of 1.8 ± 0.1 m. Assessments were conducted on a uniaxial force platform. The variables analyzed are peak force (PF), rate of force development (RFD), and impulse. Intra-test reliability was evaluated using the coefficient of variation (CV), intraclass correlation coefficient (ICC), and Bland–Altman plots. <b>Results:</b> Acceptable levels of reliability were identified solely for the variable of peak force, with CV values of D = 5.7% for the dominant profile and ND = 5.4% for the non-dominant profile. Furthermore, moderate and good relative reliability were observed in peak force for the dominant (ICC = 0.706) and non-dominant (ICC = 0.819) profiles, respectively. However, the remaining time-related variables, RFD and impulse, did not achieve acceptable levels of absolute reliability (CV > 10%) and displayed poor to moderate relative reliability. <b>Conclusions</b>: In summary, PF during the hip adductor isometric strength test demonstrated acceptable absolute and commendable relative reliability. Conversely, the time-related variables, specifically RFD and impulse, yielded unsatisfactory absolute and relative reliability levels.

Penulis (10)

P

Pablo Merino-Muñoz

F

Felipe Hermosilla-Palma

N

Nicolás Gómez-Álvarez

J

Jorge Pérez-Contreras

B

Bianca Miarka

C

Carlos Gomes de Oliveira

C

Ciro José Brito

L

Luciano Luporini Menegaldo

K

Kristof Kipp

E

Esteban Aedo-Muñoz

Format Sitasi

Merino-Muñoz, P., Hermosilla-Palma, F., Gómez-Álvarez, N., Pérez-Contreras, J., Miarka, B., Oliveira, C.G.d. et al. (2025). New Hip Adductor Isometric Strength Test on Force Platform Shows Good and Acceptable Intra-Test Reliability for Peak Force Measurement. https://doi.org/10.3390/biomechanics5020023

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.3390/biomechanics5020023
Informasi Jurnal
Tahun Terbit
2025
Sumber Database
DOAJ
DOI
10.3390/biomechanics5020023
Akses
Open Access ✓