DOAJ Open Access 2022

An Egyptian study to assess the accuracy and reliability of CAD-RADS CT coronary angiography algorithm in the evaluation of coronary artery disease

Mena E. Y. Ekladious Mounir Sobhy Guirguis Ahmed Mohammed Haggag Ahmed S. Abdelrahman

Abstrak

Abstract Background Multidetector computed tomography angiography (MDCT) is a non-invasive examination for coronary artery disease. Coronary artery disease reporting and data system (CAD-RADS) is a structured reporting system that successfully facilitated communication with clinicians. Our study aimed to assess the accuracy as well as the agreement of the CAD-RADS system with the conventional angiography results. Results 48 patients were enrolled in this prospective study, all patients underwent MDCT coronary angiography and conventional coronary artery angiography. An excellent inter method agreement between coronary CT angiography (CCTA) and conventional coronary angiography was noted for the left main trunk (LMT) with k = 1 (p < 0.001). An excellent inter method agreement was found for the proximal, mid- and distal segments of the left anterior descending artery (LAD) and the second diagonal segment, with k = 1, 0.842 0.886 and 0.886, respectively (p < 0.001). A good agreement was noted at the first diagonal segment with k = 0.765 (p < 0.001). An excellent inter-method agreement was found for the proximal, mid- and distal segments of the left circumflex artery (LCx) and the obtuse marginal branch, with k = 0.838, 0.846, 1 and 0.846, respectively (p < 0.001). An excellent agreement was found for the proximal and mid-segments of the right coronary artery (RCA) and the posterior descending artery, with k = 1 for all segments (p < 0.001), yet a good agreement was noted at its distal segment with k = 0.782 (p < 0.001). The overall per-patient sensitivity, specificity and accuracy of the CT coronary angiography were 92.9%, 90% and 91.7% respectively. Conclusions The CAD-RADS algorithm and invasive coronary angiography agreed perfectly; thus, CT coronary angiography can be used as the first screening test and the invasive coronary angiography can be spared for cases requiring intervention.

Penulis (4)

M

Mena E. Y. Ekladious

M

Mounir Sobhy Guirguis

A

Ahmed Mohammed Haggag

A

Ahmed S. Abdelrahman

Format Sitasi

Ekladious, M.E.Y., Guirguis, M.S., Haggag, A.M., Abdelrahman, A.S. (2022). An Egyptian study to assess the accuracy and reliability of CAD-RADS CT coronary angiography algorithm in the evaluation of coronary artery disease. https://doi.org/10.1186/s43055-022-00705-3

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.1186/s43055-022-00705-3
Informasi Jurnal
Tahun Terbit
2022
Sumber Database
DOAJ
DOI
10.1186/s43055-022-00705-3
Akses
Open Access ✓