Wall conditions in WEST during operations with a new ITER grade, actively cooled divertor

A. Gallo Ph. Moreau D. Douai T. Alarcon K. Afonin +25 lainnya

Abstrak

Future fusion reactors like ITER and DEMO will have all-tungsten (W) walls and long pulses. These features will make wall conditioning more difficult than in most of the existing devices. The W Environment Steady-state Tokamak (WEST) is one of the few long pulse (364 s) fusion devices with actively cooled W plasma-facing components in the world. WEST is a unique test bed to study impurity migration and plasma density control via reactor relevant wall conditioning techniques. The phase II of WEST operations began in 2022, after the installation of a new lower divertor, now entirely equipped with actively cooled, ITER grade, W monoblocks. After pump down, we baked WEST between 90 °C and 170 °C for ∼2 weeks. After 82.5 h at 90 °C and 33 h at 170 °C, vacuum conditions were stable with a vessel pressure of 6x10-5 Pa and mass spectra dominated by H2 molecules. While at 170 °C, we performed ∼40 h of D2 glow discharge cleaning (GDC) and ∼5 h of glow discharge boronization (GDB), using a 15 %-85 % B2D6-He mix and a total boron mass of ∼12 g. This was the very first GDB at such high temperature for WEST. The whole wall conditioning sequence led to a ∼10 times reduction of the H2O signal as well as to a ∼3 times reduction of the O2 signal, according to mass spectra. Once back to 70 °C, the vessel pressure was 5.5x10-6 Pa and plasma restart was seamless with ∼30 s cumulated over the very first 5 pulses and an Ohmic radiated power fraction Frad = 0.6, showing successful conditioning of the new ITER grade divertor. The effect of the first, ‘hot’ GDB faded with a characteristic cumulative injected energy of 2.45 GJ and saturation towards Frad ∼0.8. After 1.4 h and 7.5 GJ of cumulative plasma time and injected energy, we carried out a second GDB, this time at 70 °C. This ‘cold’ GDB initially led to a much lower Ohmic Frad = 0.3–0.4 but the effect lasted ∼7 times less, with a characteristic cumulative injected energy of 0.37 GJ. At the end of the campaign, we cumulated ∼3h and ∼30 GJ through repetitive, minute long pulses without any boronization. Throughout this 4-weeks-long experiment, Frad in the 4 MW heating phase evolved only marginally (from 0.5 to 0.55). This increase is mostly due to the build-up of re/co-deposited layers on both lower divertor targets.

Penulis (30)

A

A. Gallo

P

Ph. Moreau

D

D. Douai

T

T. Alarcon

K

K. Afonin

V

V. Anzallo

R

R. Bisson

J

J. Bucalossi

E

E. Caprin

Y

Y. Corre

M

M. De Combarieu

C

C. Desgranges

P

P. Devynck

A

A. Ekedahl

N

N. Fedorczak

J

J. Gaspar

A

A. Grosjean

C

C. Guillemaut

R

R. Guirlet

J

J.P. Gunn

J

J. Hillairet

T

T. Loarer

P

P. Maget

P

P. Manas

J

J. Morales

F

F.P. Pellissier

E

E. Tsitrone

K

K. Krieger

A

A. Hakola

A

A. Widdowson

Format Sitasi

Gallo, A., Moreau, P., Douai, D., Alarcon, T., Afonin, K., Anzallo, V. et al. (2024). Wall conditions in WEST during operations with a new ITER grade, actively cooled divertor. https://doi.org/10.1016/j.nme.2024.101741

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.1016/j.nme.2024.101741
Informasi Jurnal
Tahun Terbit
2024
Sumber Database
DOAJ
DOI
10.1016/j.nme.2024.101741
Akses
Open Access ✓