In the present study, iodine-131 S values (rT ← thyroid) were calculated for 30 target organs and tissues using the most recently developed Korean reference computational phantoms. The calculated S values were then compared with those of the International Commission on Radiological Protection (ICRP) reference computational phantoms to investigate the dosimetric impact of the Korean S values against those of the ICRP reference phantoms. The results showed significant differences in the S values due to the different anatomical/morphological characteristics between the Korean and ICRP reference phantoms. Most target organs/tissues showed that the S values of the Korean reference phantoms are lower than those of the ICRP reference phantoms, by up to about 4 times (male spleen and female thymus). Exceptionally, three target organs/tissues (gonads, thyroid, and extrathoracic region) showed that the S values of the Korean reference phantoms are greater, by 1.5–3.7 times. We expect that the S values calculated in the present study will be beneficially used to estimate organ/tissue doses of Korean patients under radioiodine therapy.

Penulis (5)

Y

Yeon Soo Yeom

B

Bangho Shin

C

Chansoo Choi

H

Haegin Han

C

Chan Hyeong Kim

Format Sitasi

Yeom, Y.S., Shin, B., Choi, C., Han, H., Kim, C.H. (2022). Iodine-131 S values for use in organ dose estimation of Korean patients in radioiodine therapy. https://doi.org/10.1016/j.net.2021.08.027

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.1016/j.net.2021.08.027
Informasi Jurnal
Tahun Terbit
2022
Sumber Database
DOAJ
DOI
10.1016/j.net.2021.08.027
Akses
Open Access ✓