DOAJ Open Access 2024

Relationship Between Intraluminal Thrombus Volume and Circulating ADAMTS-13 Activity in Abdominal Aortic Aneurysms

Qasam M. Ghulam Jens P. Goetze Nikolaj Eldrup Jonas P. Eiberg

Abstrak

Introduction: Abdominal aortic aneurysms (AAAs) with intraluminal thrombus (ILT) are suggested to be more prone to rupture than AAAs without. Prior studies indicate that the von Willebrand factor (vWf) plays a role in the formation of ILT since a positive correlation between ILT volume and vWf has been shown. vWf mediates the tethering of platelets at sites of endothelial injury, and the protease ADAMTS-13 cleaves larger forms of vWf, thus counteracting the thrombosis cascade and maintaining haemostatic balance. When investigating the largest quantifiable thrombus in the human body, it was hypothesised that circulating ADAMTS-13 activity may be associated with ILT size in patients with AAA and the aim was to explore this potential relationship using 3D contrast enhanced ultrasound (3D-CEUS) for ILT volume determination. Report: In this retrospective, exploratory study, 60 patients with AAA were evaluated, and the association between ILT volume and thickness and ADAMTS-13 was estimated using 3D-CEUS. ADAMTS-13 activity was measured in plasma samples obtained the same day. No association between ILT volume (r = −0.03, p = 0.84) or ILT thickness (r = 0.02, p = 0.87) and ADAMTS-13 activity was found. Likewise, when subdividing the group into lowest and highest 50% of ADAMTS-13 activity, the half with the lowest ADAMTS-13 activity (mean ILT volume ±standard deviation [SD]: 32 ± 34 mL) did not differ from the half with the highest ADAMTS-13 activity (43 ± 24 mL) when comparing ILT volume (p = 0.172, F = 2.95) and thickness (p = 0.070). Discussion: After evaluating the largest quantifiable intraluminal thrombus in the vasculature, it was concluded that, surprisingly, circulating ADAMTS-13 activity seems unrelated to ILT formation in AAA.

Penulis (4)

Q

Qasam M. Ghulam

J

Jens P. Goetze

N

Nikolaj Eldrup

J

Jonas P. Eiberg

Format Sitasi

Ghulam, Q.M., Goetze, J.P., Eldrup, N., Eiberg, J.P. (2024). Relationship Between Intraluminal Thrombus Volume and Circulating ADAMTS-13 Activity in Abdominal Aortic Aneurysms. https://doi.org/10.1016/j.ejvsvf.2024.07.040

Akses Cepat

PDF tidak tersedia langsung

Cek di sumber asli →
Lihat di Sumber doi.org/10.1016/j.ejvsvf.2024.07.040
Informasi Jurnal
Tahun Terbit
2024
Sumber Database
DOAJ
DOI
10.1016/j.ejvsvf.2024.07.040
Akses
Open Access ✓