Amperometric Detection of Hydroquinone at Modified Ionic Liquid Graphene Composite Paste Electrode
Abstrak
The ionic liquid 1-ethyl-3-methylimidazolium bromide (EMIMBr) based graphene composite paste electrode (GrPE) was fabricated and applied for the determination of hydroquinone. By using square wave voltammetry, the electrochemical response of hydroquinone on EMIMBr-GrPE was greatly enhanced in 0.7 M phosphate buffer solution (pH 7.0). Under optimized conditions, the proposed electrode showed a linear relationship with concentration in the range of 1.0×10-6 to 1.0×10-2 m hydroquinone with limit of detection of 2.77x10’7 M. The interferences of Ba2+, Cu2+, Na+, K+, NO3’, Cl’, SO42’, glycine, glucose, fructose and sucrose were negligible. Electrochemical impedance spectroscopy indicated that the charge transfer at the electrode’solution interface was excellent. The proposed electrode was successfully applied to determine of hydroquinone in wastewater and cosmetic creams with range of recovery 97 - 104%.
Topik & Kata Kunci
Penulis (6)
Hidayahtun Nur Amirah Mustafa
Illyas Md Isa
Noorshida Mohd Ali
Norhayati Hashim
Mazlina Musa
S. Ab Ghani
Akses Cepat
PDF tidak tersedia langsung
Cek di sumber asli →- Tahun Terbit
- 2015
- Sumber Database
- DOAJ
- DOI
- 10.1016/S1452-3981(23)11173-4
- Akses
- Open Access ✓